TenantAtlas/specs/340-post-scope-contract-browser-verification-gate/findings.md
ahmido a3b21c48d8 test: add post-scope contract browser verification gate (340) (#411)
## Summary
- add the Spec 340 browser verification gate package for the post-338/339 workspace and environment scope contract
- add a bounded Pest browser smoke that verifies clean workspace origin, environment origin, explicit `environment_id` hub filtering, remembered-environment non-authority, and Provider Connections create/view/edit authority signals
- record the verification inventory, matrix, findings, checklist, and audit report under `specs/340-post-scope-contract-browser-verification-gate/`
- document a `GO` recommendation with no confirmed P1/P2 drift and one backlog wording follow-up
- keep the change verification-only with no runtime behavior, schema, or route-family changes

## Validation
- `cd apps/platform && ./vendor/bin/sail artisan test --compact tests/Browser/Spec340PostScopeContractVerificationSmokeTest.php`
- `cd apps/platform && ./vendor/bin/sail artisan test --compact tests/Feature/ProviderConnections --filter=ScopeHardening`
- `cd apps/platform && ./vendor/bin/sail bin pint --dirty --format agent`
- `git diff --check --no-index /dev/null apps/platform/tests/Browser/Spec340PostScopeContractVerificationSmokeTest.php`
- `git diff --check`

## Notes
- Livewire v4 compliance unchanged
- Filament provider registration remains in `apps/platform/bootstrap/providers.php`
- no globally searchable resource behavior changed
- no destructive action behavior changed or executed in this verification gate
- no new Filament assets; deploy `filament:assets` posture is unchanged

Co-authored-by: Ahmed Darrazi <ahmed.darrazi@live.de>
Reviewed-on: #411
2026-05-31 14:37:30 +00:00

44 lines
2.4 KiB
Markdown

# Spec 340 Findings
## Severity Definitions
- `P1`: Critical scope, authorization, credential-adjacent, or cross-environment ambiguity that blocks new feature work.
- `P2`: Confirmed scope-contract drift that should be fixed before adjacent work compounds it, but without immediate credential/security risk.
- `P3`: Bounded polish or clarity issue that does not block go/no-go.
- `backlog`: Non-blocking productization or broader follow-up outside this verification gate.
- `blocked`: Missing route, data, auth, or tooling prevented proof and must not be treated as pass.
- `not-applicable`: Surface is not reachable or not relevant to the active contract in current repo truth.
## P1 Findings
None confirmed.
## P2 Findings
None confirmed.
## P3 Findings
None confirmed.
## Backlog Findings
### B-340-001 Evidence Overview topbar wording should be reviewed in a future copy/productization pass
- **Surface**: Evidence Overview helper copy.
- **Evidence**: `apps/platform/app/Filament/Pages/Monitoring/EvidenceOverview.php` contains the helper text `Use the Environment scope control in the top bar to choose an authorized environment.`
- **Classification**: backlog, not P1/P2.
- **Reason**: Browser evidence confirms clean Workspace Hubs do not silently consume remembered environment state and filtered hubs use explicit `environment_id`; this wording does not itself apply a hidden filter. It can still be reviewed later because it may blur the distinction between topbar environment context and local hub filtering.
- **Smallest next action**: handle in a future Evidence Overview copy/productization spec if product review wants stricter local-filter language.
- **Why not fixed here**: Spec 340 is verification-only with `No UI surface impact`; changing runtime UI copy would exceed the no-runtime-change posture without P1/P2 browser drift.
## Blocked Checks
None currently blocked. The implementation uses the existing Spec 322 browser harness to create deterministic workspace, environment, provider connection, evidence, alert, audit, review, decision, and operation records.
## Notes
- No screenshots containing credential-adjacent or sensitive payload data were captured.
- Destructive or external-provider actions were not executed.
- Search for topbar/local-filter copy found no instruction that the topbar acts as a local hub filter; `B-340-001` is a non-blocking wording follow-up only.