Spec 379 Runtime Validation Evidence

Date: 2026-06-14

Baseline

  • Branch: 379-management-report-pdf-runtime
  • Starting HEAD: d43ebcb4 feat(report): implement management report pdf v1 (#449)
  • Initial dirty state: only specs/379-management-report-pdf-runtime/ was untracked.
  • Spec 378 files verified:
    • docker-compose.yml
    • apps/platform/config/tenantpilot.php
    • apps/platform/app/Services/Pdf/PdfRenderingGateway.php
    • apps/platform/tests/Unit/Pdf/Spec378PdfRenderingGatewayTest.php

Local Runtime Controls

  • Gotenberg image remains pinned to gotenberg/gotenberg:8.34.0-chromium.
  • No public Gotenberg port is exposed by the gotenberg service.
  • Runtime safeguards remain configured:
    • API_DISABLE_DOWNLOAD_FROM=true
    • WEBHOOK_DISABLE=true
    • CHROMIUM_ALLOW_FILE_ACCESS_FROM_FILES=true
    • CHROMIUM_ALLOW_LIST=^file:///tmp/.*$
    • CHROMIUM_DENY_PRIVATE_IPS=true
    • CHROMIUM_DENY_PUBLIC_IPS=true
    • timeout, body-limit, queue, and concurrency env controls remain present.
  • docs/deployment-checklist.md documents the pinned image, internal service URL, and renderer hardening controls.
  • Local validation on 2026-06-15 confirmed that CHROMIUM_ALLOW_LIST=^$ makes /forms/chromium/convert/html return 403 Forbidden because Chromium must navigate to Gotenberg's temporary file:///tmp/.../index.html. The allow-list remains restricted to that internal file path and external fetches remain disabled.

Staging/Dokploy Validation

Staging/Dokploy runtime validation was not executable from this local workspace. Generation therefore remains blocked by default through:

  • TENANTPILOT_PDF_RENDERER_RUNTIME_VALIDATED=false
  • tenantpilot.pdf_renderer.runtime_validated
  • ManagementReportPdfRuntimeGate

To enable management PDF generation in Staging/Production, validate the deployed Gotenberg container/runtime path first, then set TENANTPILOT_PDF_RENDERER_RUNTIME_VALIDATED=true in the environment.

Verification Commands

  • cd apps/platform && ./vendor/bin/sail artisan test --compact --filter=Spec379
    • Result: 7 passed, 81 assertions.
  • cd apps/platform && ./vendor/bin/sail php vendor/bin/pest tests/Browser/Spec379ManagementReportPdfSmokeTest.php --compact
    • Result: 1 passed, 12 assertions.
  • cd apps/platform && ./vendor/bin/sail artisan test --compact --filter=Spec378
    • Result: 11 passed, 44 assertions.
  • cd apps/platform && ./vendor/bin/sail artisan test --compact --filter=Spec357
    • Result: 13 passed, 108 assertions.
  • cd apps/platform && ./vendor/bin/sail artisan test --compact --filter=Spec366
    • Result: 9 passed, 181 assertions.
  • cd apps/platform && ./vendor/bin/sail artisan test --compact tests/Feature/ReviewPack/ReviewPackDownloadTest.php tests/Feature/ReviewPack/ReviewPackResourceTest.php tests/Unit/Pdf/Spec378PdfRenderingGatewayTest.php
    • Result: 49 passed, 268 assertions.
  • cd apps/platform && ./vendor/bin/sail pint ...
    • Result: PASS on changed runtime/test files.
  • git diff --check
    • Result: PASS.

Guard Notes

The optional guard command below was run and produced two pre-existing failures unrelated to Spec 379:

  • cd apps/platform && ./vendor/bin/sail artisan test --compact tests/Feature/Guards/OperationLifecycleOpsUxGuardTest.php tests/Feature/Guards/ActionSurfaceContractTest.php
    • ActionSurfaceContractTest: operation registry URL assertion expects no navigation context, but current code returns an operations-index navigation context.
    • ActionSurfaceContractTest: required-permissions page assertion expects Start verification, which the current page no longer renders.

Both failures reproduce in isolation and no Spec379 code path is involved.